Data
Logging & Testing
|
|
|
|
|
|
D102 Data Logger System
A 43-channel analogue and digital computer interface with Windows
compatible menu driven software for data logging and control of
Engineering Laboratory Teaching and Research Equipment.
The software allows transducers to be easily and quickly configured
to return data in the engineering units selected by the operator and
for these configurations to be simply stored using a standard
Windows format. The software includes a number of numerical and
graphic display options and data files are easily exported to Excel
or another spreadsheet format for report writing. Comprehensive
instruction manuals are supplied suitable for student operation of
the hardware and software.
Specifically designed transducers can be supplied to measure: pressure,
temperature, flow rate, force, displacement, humidity, power, current,
voltage, rotational speed and heat flow for most fluids and applications
utilising the onboard power supplies ( ±5v, ±15v and +12v)
The interface has a simple and logical command format and a separate
additional manual is available for those users who wish to write
software for specialised control and instrumentation applications. A
total of three Data Loggers may be connected to a single computer. For
specialised applications calibration to traceable international
standards is available. |
|
|
|
|
|
|
|
D102A Refrigeration and Air Conditioning Transducers
A standard transducer
package to measure the
performance of most commercial refrigerating and
air-conditioning systems in conjunction with the D102
Data Logger System. The transducers supplied include:
• Thermocouple Sensors
• High/Low Pressure Refrigerant Transducer
• Refrigerant Flow Meter
• Water Flow Meter
• Load Cell
• Differential Air Pressure Transducer
• Current Transducer
• Relay Burst Firing Switch
• Rotational/Proximity Switch.
This package is supplied with software pre-configured for the
transducers and a detailed instruction manual. Additional optional
software is available to calculate pressure enthalpy data and plot
refrigerant cycle diagrams with up to 15 points in the circuit and
for 35 different refrigerant types. Separate software for
psychrometric data calculations and diagrams is also available.
|
|
|
|
|
|
|
|
HFS300 Data Logging System with Heat Flow Transducers
A D102 Data Logging System complete with a standard
transducer package to measure
the heat transfer through the walls floors and
ceilings of buildings. The transducers
supplied include eight patented heat flow
transducers, two signal conditioning boxes and five class 1 type T
thermocouples.
5m extension leads, installation equipment and a hand
held digital display enable the system to be easily used on
site. The unit is supplied with software pre-configured for the
transducers and with a detailed
i nstruction manual.
|
|
|
|
|
|
|
|
HTS700 Temperature and Humidity Control
Specifically designed for use with the Test Room this package comprises
a specially modified air conditioning plant operating on ozone friendly
refrigerant that gives PID controlled room temperatures.
A steam generator and digital control system allows precise humidity
control. The range of control conditions are specifically designed for
testing of domestic and small commercial refrigerators to recognised
international standards.The Temperature and Humidity Control system is
also applicable to existing rooms with specific volumes and insulation
levels. Details available on request.
|
|
|
|
|
|
|
|
HTS700B Test Room
This is a thermally insulated walk in test room that is designed for use
with the optional Temperature and Humidity Control and the Data Logger
System.
The Test Room is suitable for thermal load testing of domestic and small
commercial refrigerators as well as other domestic appliances to
recognised international standards when used in conjunction with the
Temperature and Humidity Control. An extension package is also available
as an optional extra.
|
|
|
|
|
|
|
|
HTS700C Voltage Control and Transducer Panel
This wall mounted unit houses a 10A variable voltage transformer,
analogue voltmeter and digital wattmeter.The digital wattmeter has DC
voltage outputs that may be used to transmit signals representing mains
Voltage, Load Current and Load Power to the Data Logger System.The unit
is designed to allow testing of domestic appliances at elevated
temperature conditions within the Test Room and at voltages between 0
and 105% of the local supply. Other variants offer three phase voltage
control and frequency conversion and monitoring.
|
|
|
|
|
|
|
|
D102B Remote Connection Panel
This panel replicates the Data Logger System screw terminals and is
designed to allow transducers to be easily connected and disconnected
within the Test Room while the Data Logger System remains at external
ambient conditions.
|
|
|
|
|
|
|
|
D102C Power Consumption Meter
This meter is specifically designed to allow measurement of domestic
appliance power consumption using the Data Logger System while under
elevated ambient conditions in the Test Room.The meter has a digital
display, selectable 0-20 or 0-40kWh range and will accept loads up to
10Amps and 50/60Hz.
|
|
|
|
|
|
|
|
D102D Logic Relay Transducer
This device enables the Data Logger System to record the cycle time of
domestic appliances that use on/off thermostats or controls.
|
|
|
|
|
|
|
|
TYL 100 Series Test Packages
These test packages conform to an international standard and are used
for load testing of domestic and commercial refrigerators and freezers.
|
|
|